The Time setting (SNTP client) function is not running normally
Check the following items.
Check item
Are the settings configured to use the time setting (SNTP server)?
Is the specified SNTP server IP address correct?
Is the connection to the specified SNTP server?
Is the specified SNTP server time within the time data range of the clock
function?
A Windows-part forced-restart cannot be run
Check the following items.
Check item
In the following settings, is WIN RESET set to "Disable"?
• [Basic Parameters]  [Operation Related Settings]  [Remote Operation
Settings]  [WIN RESET]
Was the MELIPC shutdown function run?
Windows-part forced-restart is not complete
Check the following items.
Check item
Were the following functions used for advance processing of Windows part
forced-restart?
• CCPU_MELIPCShutdown
• CCPU_WinReset
Advance processing registered by the user for the Windows part forced-restart
function did not end normally.
Shutdown of this product is not complete
Check the following items.
Check item
Is the WIN RDY LED flashing?
Were the following functions used for advance processing of the MELIPC
shutdown function?
• CCPU_MELIPCShutdown
• CCPU_WinReset
Advance processing registered by the user for the MELIPC shutdown function
did not end normally.
Corrective action
Change the settings to use the time setting (SNTP server)?
Check the IP address of the SNTP server settings, and then review the
settings if necessary.
• Check whether communication with the SNTP server is possible.
• Check whether the Ethernet cable is connected to the Ethernet port (CH1).
Check whether the SNTP server time is within the clock data range of this
product.
Corrective action
Set WIN RESET to "Enable".
Turn the power supply of this product OFF to ON.
Corrective action
Switch the power supply of this product OFF to ON, review the advance
processing registered by the user for the Windows part forced-restart function,
and then register again.
Switch the power supply of this product OFF to ON, review the advance
processing registered by the user for the Windows part forced-restart function,
and then register again.
Corrective action
Page 201 If the WIN RDY LED is not lit
Switch the power supply of this product OFF to ON, and then review the
advance processing registered by the user for the MELIPC shutdown function.
Switch the power supply of this product OFF to ON, review the advance
processing registered by the user for the MELIPC shutdown function, and then
register again.