Power-Up LED Error Codes,
CXT LED
Codes
If the system enters the console program, then run the MEMORY
diagnostics and interpret the error information using
The SHOW ERROR command
Diagnostic information (Chapter 4)
LED Code
Description
20
Machine Check
21
CELL Fill mem with test pattern data
22
CELL Forward Rd/Compare/Complement/Wr
23
CELL Reverse Rd/Compare/Complement/Wr
24
ADDR Fill mem with addresses as data
25
ADDR Read/Compare data = address
26-2a
Reserved
2b
LLSC load-locked/store-conditional tests
2c
BCTP Bcache Tag Parity detection
2d
ECC detection
2e
Reserved
2f
Clear memory to zeros
The following LED codes represent continued power-up testing. If
an error occurs during this testing sequence, the system displays
a hexadecimal code plus FRU and error code information on the
screen.
If the system enters the console program, then run the CXT
diagnostics and interpret the error information using
SHOW ERROR command
Diagnostic information (Chapter 4)
Diagnostic error messages (Appendix C)
If the unit does not enter the console program (>>> prompt
displayed on monitor or DD code displayed on the LEDs), then
use Tables 6–6 and 6–7 to isolate the failed FRU.
Continued
Continued on next page
6–7