MOUNTING THE SENSOR Secure the sensor at the desired position in the system (use the adapter plate if necessary). Do not tighten the screws until alignment has been completed (see page 6), and then check that the sensor is functioning correctly.
CONNECTING THE SENSOR When connecting to the PLC, take into account the pin assignment specifi ed below * Available for certain variants only (for further infor- mation, see the data sheet) ** Activation input possible depending on variant RECEIVER TRANSMITTER OUT2* OUT1 NC**...
ALIGNING THE SENSOR Align the sensor so that the light spot hits the refl ector – continue to page 9 the light beam is directed toward the receiver. The transmitter and receiver must be mounted on one axis – continue to page 11 the light beam hits the part of the object by which it is to be detected –...
RETRO-REFLECTIVE PHOTOELECTRIC SENSOR SENSITIVITY ADJUSTMENT * When an object enters the light axis, the yellow status LED must go out. If this is not the case, the sensitivity must be adjusted. Using the screwdriver, turn the potentiometer until the yellow status LED goes out. * Only on variants with potentiometer...
Page 11
THROUGHBEAM PHOTOELECTRIC SENSOR SENSITIVITY ADJUSTMENT * When an object enters the light axis, the yellow status LED must go out. If this is not the case, the sensitivity must be adjusted. Using the screwdriver, turn the potentiometer until the yellow status LED goes out. * Only on variants with potentiometer...
ADJUSTING THE SENSOR Place the object at the desired distance to the sensor. Turn the multiturn potentiometer counter- clockwise until the yellow status LED goes out. Then turn it clockwise slightly until the LED lights up again. Check the reproducibility by moving the object.
Page 14
For more than 50 years, we have been developing, producing, and marketing effi cient sensor solutions for industrial automation. Technological competence centers Technological competence centers Locations Distributors...
Page 16
YOU HAVE QUESTIONS? I'M HERE TO HELP. Leuze electronic, Inc. 55395 Lyon Industrial Drive US-New Hudson, MI 48165 Tel.: +1 248 486-4466 info@leuzeusa.com www.leuzeusa.com Chantel Allard TechSupport.US@leuze.com Phone: +1 (248) 446-2484...