Smart Touch: Photo Eye / Reflecti-Guard (Rg-R) - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
t
mart
oucH
1. Connect photo eye wiring.
NOTE: Run a jumper between photo eye -24V and CM terminals.
2. Turn ON power.
3. Access the Installer Menu and configure SENSOR setting
according to the entrapment area that the photo eye is
monitoring. Refer to table on page 10.
CAUTION
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes. The
sensor becomes actively powered when the gate
operator's motor runs.
Power Supply Board
+24V
Reflecti-GUARD Photo Eye
NOTE: If you receive an Alert, "!ACTION BLOCKED" "Photo
Eye Open" PEO or "Photo Eye Close" PEC, take steps to align
the photo eye. Refer to Photo Eye Alignment on page 12.
30
D0726 Rev. J
: p
e
Hoto
ye
Connect NC relay
wire to SENSOR 1,
2, or 3.
To pull 3 wires instead of
4, jumper, PWR Relay to
CM terminal
UL 325 - 2016 HySecurity Monitored Sensors
/ r
-G
efLectI
DRIVE
1
STOP BUTTON
2
OPEN BUTTON
3
CLOSE BUTTON
REMOTE OPEN AND
4
RADIO CONTROL
5
OPEN/CLOSE
6
OPEN PARTIAL
INTERLOCK OPEN
7
TIME CLOCK OPEN
8
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
9
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
10
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
11
VEHICLE DETECTOR
SHADOW/RESET
12
VEHICLE DETECTOR
SENSOR 1
14
SENSOR
COM
15
16
DO NOT USE
17
SENSOR 2
18
DO NOT USE
19
SENSOR 3
20
DO NOT USE
CHARGER
21
AC LOSS
22
LOCK INTERLOCK
23
EMERG CLOSE
24
FIRE DEPT OPEN
Smart Touch Controller
LED
LIMIT
DUAL GATE
RPM
COM
(rG-r)
uard
S1 0
SENSOR #1 TYPE
S1 4 (EYE OPEN)
SENSOR #1 TYPE
POWER
RS485
COM
NO
STATUS
HySecurity
MX000585
VERSION
S/N
RADIO OPTIONS
S 1
A
B
COM
OPEN
+24V
+24V
COM
© 2016 www.hysecurity.com
Installer Menu
showing Sensor 1
set to Eye Open
(Option #4)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents