8. Monitoring Settings
Transmission Test Execution
If the SNMP Manager cannot receive an SNMP test trap, check that the network has no trouble, and the
settings for the ETERNUS DX are correct.
Is the LAN between the monitoring server and ETERNUS DX connected correctly?
•
Execute the "ping" command from the monitoring server, and confirm the reply from the ETERNUS DX.
IMPORTANT
When "ICMP" is disabled by the firewall settings for ETERNUS Web GUI, the "ping" command
cannot be used for confirmation. Enable "ICMP" before executing the "ping" command.
Is the monitoring software set correctly to monitor the ETERNUS DX?
•
•
Are the SNMP environment settings and the transmission destination for the SNMP Trap set correctly on
the ETERNUS DX?
Send Test E-mail
Perform an e-mail transmission test to check that the e-mail can be sent from the ETERNUS DX to the specified
e-mail address.
The procedure to send a test e-mail is as follows:
1
On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
2
In [Category], click [Network].
The [Network] screen appears.
3
In [Action], click [Setup E-Mail Notification].
The [Setup E-Mail Notification] screen appears.
4
Click the [Send Test E-Mail] button.
177
Configuration Guide (Basic)