Configure the
the Supervisor
Supervisor Module
Configure
Configure
the
Supervisor
Use this procedure to view current network status
of each Supervisor Module (36) in the Intelligent
Paint Kitchen system, to change the network IP
configuration settings if necessary, and to confirm
communication by pinging the system.
NOTE:
NOTE: Do not modify these settings unless instructed
NOTE:
by Graco.
1. Press
on any Run screen to enter the Setup
menu screen.
2. Press Supervisor
Supervisor Configuration
Supervisor
Configuration.
Configuration
On the Supervisor Configuration screen, do the
following:
• Press Status
Status to view the current network
Status
settings. The read-only Supervisor Status
screen displays the current network settings.
Each Supervisor Module in the Intelligent Paint
Kitchen system is displayed as either Online
or Offline
Offline
Offline.
• Press IP IP IP Configuration
Configuration to change the IP
Configuration
configuration settings for the Supervisor
Module.
a. On the read-only Supervisor Network
Configuration screen, press Edit
b. On the editable Supervisor Network
Configuration screen, press one of the
data fields to be changed. Use the popup
screen to enter the network setting.
Field
Field
Field
IP Address
Subnet Mask
Gateway
c. Repeat as needed, until all the network
configuration settings are correct.
d. To enter the changes and have them take
effect, press Apply
• Press Baud
Baud Rate
Baud
Rate to change the baud rate
Rate
settings for the Supervisor Module. Press
the Supervisor
Supervisor
Supervisor Baud
Baud Rate
Baud
popup screen to enter the setting. The default
is 57600. 38400 is also available. To enter
the changes and have them take effect, press
Apply
Apply
Apply.
Verify that the baud rate settings match
the settings for the Pump Control
Module and fiber optic converter. See
Set Up a Pump Control Module for Modbus
Communication, page 47
on the Fiber Optic Converters, page
3A4030C
Module
Module
Online
Online
Edit Config
Edit
Config
Config.
Value
Value
Value
192.168.1.201
255.255.255.0
192.168.1.1
Apply.
Apply
Rate
Rate field and use the
and
Set DIP Switches
32.
Network Setup and Configuration
3. To change the IP configuration settings, press
IP IP IP Configuration
Configuration. On the read-only Supervisor
Configuration
Network Configuration screen, press Edit
4. Confirm that communication to the Supervisor
Box is working properly.
Edit Config
Edit
Config.
Config
93