Graco 25A693 Instructions Manual page 65

Intelligent paint kitchen system
Table of Contents

Advertisement

Table 4 4 4 Fields
Fields on
on the
the Station
Station Configuration
Table
Table
Fields
on
the
Station
Field
Field
Field
Description
Description
Description
Primary Tank
Select Yes
Select No
Primary VFD
Select the manufacturer of the Variable Frequency Drive/Inverter used to
control the agitator installed on the Primary Tank: Lenze
Variable Frequency Drive/Inverter (B) 17N041, 17N042, 17N043, page 16
Variable Frequency Drives/Inverters.
Select None
Primary
Select the type of agitator installed on the Primary Tank:
Agitator
• 60
60 Hz
60
• 60
60 Hz
60
• 50
50 Hz
50
• 50
50 Hz
50
For part numbers, see
Select None
Secondary
Select Yes
Tank
Select No
Secondary
Select the manufacturer of the Variable Frequency Drive/Inverter used to control
VFD
the agitator installed on the Secondary Tank: Lenze
Variable Frequency Drive/Inverter (B) 17N041, 17N042, 17N043, page 16
Variable Frequency Drives/Inverters.
Select None
Secondary
Select the type of agitator installed on the Secondary Tank:
Agitator
60 Hz
• 60
60
60 Hz
• 60
60
50 Hz
• 50
50
50 Hz
• 50
50
For part numbers, see
Select None
Fill Pump
Select Yes
the Secondary Tank.
Select No
Pump Type
Select the type of pump used to circulate fluid through the station: None
E E E - - - Flo
Flo DC
Flo
Tank Control
Select Yes
Module
Select No
Back Pressure
Select Yes
Regulator
Select No
(BPR)
3A4030C
Configuration Screen
Screen
Configuration
Screen
Yes if the station has a Primary Tank.
Yes
No if there is no Primary Tank installed.
No
None
None if there is no Variable Frequency Drive/Inverter for the Primary Tank.
Hz
Hz Direct
Direct Drive
Direct
Drive
Drive
Hz Back
Hz
Back Gear
Back
Gear
Gear
Hz Direct
Hz
Direct Drive
Direct
Drive
Drive
Hz
Hz Back
Back Gear
Back
Gear
Gear
Appendix F: Agitator Part Numbers, page
None if no agitator is installed.
None
Yes if the station has a Secondary Tank.
Yes
No if there is no Secondary Tank installed.
No
None if there is no Variable Frequency Drive/Inverter for the Secondary Tank.
None
Hz Direct
Direct Drive
Drive
Hz
Direct
Drive
Hz Back
Back Gear
Gear
Hz
Back
Gear
Hz Direct
Direct Drive
Drive
Hz
Direct
Drive
Hz Back
Back Gear
Gear
Hz
Back
Gear
Appendix F: Agitator Part Numbers, page
None if no agitator is installed.
None
Yes if a pneumatic remote transfer pump is used to fill the Primary Tank from
Yes
No if there is no transfer pump installed.
No
DC x x x 2 2 2
DC
Yes if the Secondary Tank has a Tank Control Module.
Yes
No if there is no Tank Control Module.
No
Yes if the station has an installed back pressure regulator.
Yes
No if there is no back pressure regulator installed.
No
Using the Setup Screens
Lenze or PowerFlex
Lenze
PowerFlex 4M
PowerFlex
159.
Lenze or PowerFlex
PowerFlex 4M
4M. See
Lenze
PowerFlex
4M
159.
None, E E E - - - Flo
None
4M. See
4M
for supported
for supported
Flo DC
Flo
DC, or
DC
65