Repair
Replace a a a Fiber
Fiber Optic
Replace
Replace
Fiber
1. Disconnect the power.
2. Disconnect the + (white/blue) and – (blue)
electrical wires.
3. Remove the fiber optic converter (38) from the
DIN rail.
4. Attach the new fiber optic converter (38) to the
DIN rail.
5. Connect the + (white/blue) wire to terminal C.
Connect the – (blue) wire to terminal B.
NOTE: In the Supervisor Box, the wires originate
NOTE:
NOTE:
from the Supervisor Module. In the Expansion
Box, the wires originate from the power supply.
Wire
Wire
Wire
Figure 96 Connecting Fiber Optic Converter
Wires
138
Optic Converter
Converter
Optic
Converter
Termi-
Termi-
Termi-
Color
Color
Color
nal
nal
nal
B
White-
/Blue
C
Blue-
/White
Replace the
the Supervisor
Supervisor Module
Replace
Replace
the
Supervisor
1. Disconnect the power.
2. Disconnect + (red, white/blue) wires from
connectors B, 7, and 8. Disconnect – (blue,
black) wires from connectors A, 5, and 6.
3. Remove the Supervisor Module (36) from the
DIN rail.
4. Install the new Supervisor Module onto the DIN
rail.
5. Connect the + (white/blue) wire from the fiber
optic converter (38) to terminal A on the ACS.
Connect the – (blue/white) wire from the fiber
optic converter to terminal B.
6. Connect the + (red) wire from the power supply
(35) to terminal 8 on the ACS. Connect the –
(black) wire from the power supply to terminal 6.
7. Connect the + (red) wire from terminal 6 on the
Ethernet switch (37) to terminal 6 on the ACS.
Connect the – (black) wire from terminal 5 on the
Ethernet switch to terminal 5 on the ACS.
Wire
Wire
Wire
Figure 97 Connecting the Supervisor Module
Wires
Module
Module
Color
Color
Color
Red
Blue
Black
White/Blue
Blue/White
3A4030C