Use this procedure to configure Graco part numbers
25D298 and 25D294 (Endress+Hauser FMP50
Radar Level Sensors).
NOTE:
NOTE: For complete warnings and operation
NOTE:
instructions, see the manufacturer's manual that is
shipped with the product.
Key Name
Name
Function
Key
Key
Name
Function
Function
-
Minus
For menus and submenus, press
key
this key to move the selection bar
up in a list.
For text and numeric fields, press
this key to move the selection bar
to the left (backward).
+
Plus
For menus and submenus, press
key
this key to move the selection bar
down in a list.
For text and numeric fields, press
this key to move the selection bar
to the right (forward).
E
Enter
Press this key to enter the setup
key
screen (main menu).
Press this key for two seconds to
open the context menu.
Press this key to open the selected
menu, submenu, or parameter.
Press the key for two seconds to
open the help text for the selected
parameter.
For text and numeric fields, press
this key to open the selected group
or perform the selected action.
Press the key for two seconds on a
selected parameter to confirm and
enter the edited parameter value.
-
Es-
For menus and submenus, press
and
cape
these two keys to exit the current
+
key
menu level and go to the next
higher level.
For help text, press these two
keys to close the help text for a
parameter.
Press these two keys for two
seconds to return to the home
screen.
For text and numeric fields, press
these two keys to close the editor
without applying changes.
52
Level Sensor
Sensor
Level
Sensor
Press E E E to enter the setup screen, press + + + to highlight
the setup menu, and then press E E E to enter the setup
menu. Enter the setup information for each screen.
Setup Screen
Setup
Setup
Screen
Screen
Function
Function
Function
Device tag
Enter a unique name for the
measuring point.
Distance unit
Select the distance unit for
calibration:
• Meters (default)
• Millimeters
• Feet
• Inches
Tank type
Select the tank type:
• Metallic
• Bypass/pipe
• Non-metallic
• Mounted outside
• Coaxial
NOTES:
The Medium
Medium type
for these options to be available.
Depending on the probe, some
options might not be available or
additional options might appear.
For coax probes and probes with
a metallic center washer, the tank
type corresponds to the type of
probe and cannot be changed.
Medium group
Select the medium group to
specify the dielectric constant
(DC) of the medium:
• Water based (DC >=4)
• Others
NOTES:
The Medium
Medium type
for these options to be available.
The Medium
changed later; however, the
Medium
Medium group
Medium
The measuring range can be
reduced for small dielectric
constants.
Empty
Enter the distance (LN) between
calibration
the process connection (LR) and
the minimum level (0%).
Medium
type must be Liquid
type
Liquid
Liquid
Medium
type
type must be Liquid
Liquid
Liquid
Medium property
property can be
Medium
property
group
group remains the same.