Graco 25A693 Instructions Manual page 132

Intelligent paint kitchen system
Table of Contents

Advertisement

Troubleshooting
Problem
Problem
Problem
The Variable
Frequency Drive/
Inverter (B) cannot
communicate with
the electric agitator.
The Radar Level
Sensor (M, T) will not
power on.
The Touchscreen
Box (J) cannot
communicate with
the Supervisor Box
(A).
132
Cause
Cause
Cause
The wiring is incorrect.
Fiber ports are
backwards.
The fiber cable is set up
incorrectly.
The parameters are set
up incorrectly.
The wiring is set up
incorrectly.
Node communication is
not enabled.
The Radar Level Sensor
is not connected to the
correct port.
The power is not turned
on.
The IP settings are
incorrect.
The Ethernet cables are
plugged into the wrong
port.
Solution
Solution
Solution
Check the Modbus wiring between the Supervisor
Module and the fiber to serial converter.
• A = GND
• B = Data B(+) – Blue/White
• C = Data A(-) – White/Blue
Verify the fiber port setup. See
Modbus (RS-485) Wiring, page
• RX from ADCM Port 1 is connected to Fiber to Serial
Converter TX.
• TX from ADCM Port 2 is connected to Fiber to serial
Converter RX.
Verify the fiber cable setup. See
Tank Control Modules to the Supervisor Box, page
Check all parameters for your version (Lenze
SMVector or Allen Bradley PowerFlex 4M). See
Digital Input Configuration, page
Verify the wiring. See
Wire the Variable Frequency
Drive/Inverter to the Supervisor Module, page
Turn on node communication. See
Turn on Node Communication, page
Verify that the Radar Level Sensor (M, T) is connected to
the correct port. See
Connect a Radar Level Sensor to a
Pump Control Module or Tank Control Module, page
Make sure the box is enabled to turn on power in the
setup screens. See
Connect a Radar Level Sensor to a
Pump Control Module or Tank Control Module, page
Verify that the IP address settings for Port 2 are correct.
See
Network Setup and Configuration, page
Verify that the Ethernet connection between the
Supervisor Box and the Touchscreen Box. See
the Supervisor Box to the Touchscreen Box, page
34.
Connect Pump and
38.
28.
36.
67.
27.
27.
92.
Connect
41.
3A4030C

Advertisement

Table of Contents
loading

This manual is also suitable for:

25a84325a830

Table of Contents