E-Flo DC Pump Status Read only. Displays current operating conditions in the pump:
12
Pump Size
13
Arrow
3A4030C
Description
Description
Description
Indicates the current status of the pump.
indicates that the pump is stopped.
indicates that the pump is transferring fluid to the Primary Tank.
Displays the current Back Pressure Regulator setting in %.
Press to display a keypad and change the Back Pressure Regulator
setting.
Displays the operating speed (in RPM, Hz, or %) of the primary electric
agitator installed in the circulation.
Press to display a keypad and change the agitator speed.
Press the image of a Primary Tank to display the Primary Agitator Enable
popup screen. Use the popup to enable or disable the selected agitator.
If the agitator is operating, its blades are shown in motion on this screen.
Displays the operating speed (in RPM, Hz, or %) of the secondary electric
agitator installed in the circulation.
Press to display a keypad and change the agitator speed.
Press the image of a Secondary Tank to display the Secondary Agitator
Enable popup screen. Use the popup to enable or disable the selected
agitator.
If the agitator is operating, its blades are shown in motion on this screen.
Read only. Displays the level of fluid in the Primary Tank.
Press the image of the pump to display the Profile Select popup screen.
Use the popup to enable or disable a profile for the selected pump.
• Profile: Displays the profile (0–4) that is controlling the pump's
operation.
• Mode: Off, Flow, or Pressure (If Off, the Profile is 0.)
• Cycles/min: Current speed of the pump in cycles per minute.
• Force: Current force that the pump is currently provided in a range
of 0—100%
• Flow Rate: Indicates the pump's current flow rate in cycles/min, oz/min,
cc/min, Gallons/min, or Liters/min, as chosen when the pump was
set up.
• Current Pressure for pressure transducer 1: Port 7 Pump Control
Module
• Current Pressure for pressure transducer 2: Port 10 Pump Control
Module
Read-only. Displays the configured pump size for that station on the
Pump Control Module: 220 cc, 290 cc, 750 cc, 1000 cc, 1500 cc, 2000
cc, 3000 cc, 4000 cc
See
Set Up E-Flo DC Pumps, page 68
size pump is installed.
Closed loop pressure has been assigned to that pressure transducer.
Press
to view or change the pump output pressure. For more
information, see Setup Screens 8 and 9 in the E-Flo DC Control Module
Kit manual 3A2527.
to change this setting if a different
Operation
105