Intelligent Paint Kitchen Overview
Fiber
Fiber Optic
Fiber
Optic
Optic Converter
Converter
Converter
24N978
24N978
24N978
Installed inside the Supervisor Box (A) and the
Expansion Box, each serial to fiber optic converter
sends data to and receives data from one Pump
Control Module (PD) installed in the hazardous
location of a station.
Data is sent to and from the Pump Control Module
(PD) along a fiber optic cable. A serial cable
connection is made between each fiber optic
converter and the Supervisor Module, and the fiber
optic converters within one Supervisor Box or one
Expansion Box are all wired in series to the 24 VDC
power supply.
Figure 11 Serial to Fiber Optic Converter
Item
Description
Item
Item
Description
Description
39
Serial communication connection to
Supervisor Module
40
24 VDC power connection
RX
Fiber optic cable connection; receives
data from a Pump Control Module
TX
Fiber optic cable connection; transmits
data to a Pump Control Module
A
Ground
B
Terminal Data B (+)
C
Terminal Data A (-)
D
Terminal D (not used)
E
Terminal E (not used)
18
3A4030C