Graco 25A693 Instructions Manual page 130

Intelligent paint kitchen system
Table of Contents

Advertisement

Events and Logs
Display
Applicable
Display
Display
Applicable
Applicable
Code
Code
Code
Motor
Motor
Motor
V4I_
Basic and
Advanced
V9M_
Basic and
Advanced
WCW_
Advanced
Basic and
WMC_
Advanced
WNC_
Basic and
Advanced
WNN_
Advanced
WSC_
Advanced
WSD_
Advanced
WXD_
Basic and
Advanced
130
Blink
Type
Blink
Blink
Type
Type
Code
Code
Code
3
Alarm
Voltage supplied to motor is too high.
7
Alarm
Low supply voltage detected at start up.
None
Alarm
System type mismatch; motor is an E-Flo DC dual lower
system and the display configuration does not match.
Change the display's system type on the Setup Units screen
(screen 15).
4–5
Alarm
Internal software error.
3–4
Alarm
Software versions do not match.
None
Alarm
System type mismatch; motor is an E-Flo DC single lower
system and the display configuration does not match.
Change the display's system type on the Setup Units screen
(screen 12 in dual lower mode).
None
Deviation Profile is set to 0 pressure or 0 flow.
1–5
Alarm
Invalid lower size; occurs if the unit is operated before setting
up the lower size.
4
Alarm
An internal circuit board hardware failure is detected.
Description
Description
Description
3A4030C

Advertisement

Table of Contents
loading

This manual is also suitable for:

25a84325a830

Table of Contents