Graco 25A693 Instructions Manual page 53

Intelligent paint kitchen system
Table of Contents

Advertisement

Setup Screen
Screen
Function
Setup
Setup
Screen
Function
Function
Full calibration
Enter the distance (LF) between
the minimum (0%) and the
maximum level (0%). The
minimum is the bottom of the
probe and the maximum is the
"full" level.
Level
Displays the measured level
(LL) of the material before
linearization. The unit is defined
in the Level unit setting.
Distance
Displays the distance (LD)
between the lower edge of the
flange or threaded connection
(LR) and the level (LL).
Signal quality
Displays the signal quality of the
evaluated echo.
• Strong: Exceeds the threshold
by 10 mV or more.
• Medium: Exceeds the
threshold by 5 mV or more.
• Weak: Exceeds the threshold
by less than 5 mV.
• No signal: The device cannot
find a usable echo. The system
displays an error message for
output echo lost.
NOTE: The signal quality refers
to the level/interface echo or
the end-of-probe echo. The
quality of the end-of-probe echo
is displayed in brackets.
Confirm
Specify whether the measured
distance
distance matches the actual
distance.
• Manual map: The range of
mapping is defined manually
in the Mapping
parameter.
• Distance OK: The measured
distance matches the actual
distance.
• Distance unknown: The actual
distance is unknown.
• Distance too small: The
measured distance is less than
the actual distance.
• Distance too big: The
measured distance is more
than the actual distance.
• Tank empty: The tank is
completely empty.
• Delete map: Delete the present
mapping curve.
3A4030C
Mapping end
end point
point
Mapping
end
point
Figure 61 Configuration Parameters
Ref.
Description
Description
Description
Ref.
Ref.
LD
Distance
LF
Full calibration (span)
LL
Level
LN
Length of probe
LR
Reference point of the measurement
LZ
Empty calibration (zero point)
Map an
Map
Map
an
an Empty
Empty
Empty Tank
Tank
Tank
NOTE:
NOTE:
NOTE: You must map the tank when it is empty to
ensure that it functions properly.
Use this procedure to map an empty tank.
1. Press E E E to enter the setup screen.
2. Press + + + to highlight Confirm
press E E E to enter the Confirm
3. Press + + + to highlight Delete
4. Press + + + to highlight Tank
E E E .
5. Press + + + and - - - until you reach the main menu.
Software Setup
Confirm distance
Confirm
distance and then
distance
Confirm distance
distance screen.
Confirm
distance
Delete map
map and then press E E E .
Delete
map
Tank empty
empty and then press
Tank
empty
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

25a84325a830

Table of Contents