Software Setup
Set
Set
Set Up
Up
Up a a a Tank
Tank Control
Tank
Control Module
Control
Follow these steps to set up a Tank Control Module
(TD) using the keypad and display. For complete
warnings and operation instructions, see the Tank
Control Module Kit manual 3A5991.
• Press the Up Arrow or Down Arrow key to select
the settings for the tank
• Press the Enter key to enter the selection.
1. Press the Toggle key to enter the control module
Setup screens.
2. Use the Up Arrow and Down Arrow keys to
navigate to Setup Screen 5.
Figure 52 Setup Screen 5
3. Select a control location (local
from the menu.
Figure 53 Setup Screen 5 Local or Remote
Control Location Menu
48
Module for
Module
for Modbus
for
Modbus Communication
Modbus
or remote
Communication
Communication
4. Set the Modbus node ID from 1 to 247.
Figure 54 Setup Screen 5 Modbus Node ID Field
5. Select a Modbus communications failure
notification type from the menu. Select X for
disabled or
Figure 55 Setup Screen 5 Failure Notification
Type Menu
)
6. Select the serial port baud rate from the menu.
57600 bps is standard. 38400 is also available.
Do not select 115200 because it is not compatible
with the Supervisor Module.
Figure 56 Setup Screen 5 Baud Rate Menu
7. When all control module settings are correct,
press the Exit Screen key to exit setup mode.
for deviation.