Software Setup
Control
Control Module
Control
Module
Module Software
Software
Software
Pump Control Modules and Tank Control Modules
located in each hazardous location can be set up
locally, using the keypad and display to access and
change the software settings.
Use the control module software to:
• Place the control module in Remote Control
mode. See
Set Up a Pump Control Module
for Modbus Communication, page 47
Set Up a Tank Control Module for Modbus
Communication, page
• Set the baud rate for control module
communication. The baud rate must match
the baud rate of the Supervisor Module.
See
Set Up a Pump Control Module for
Modbus Communication, page 47
Set Up a Tank Control Module for Modbus
Communication, page
• Set up the Reed Switch, Agitator Halt Drum Cover
Switch, Primary Tank High and Low Alarm Output,
and Auxiliary Solenoid. See
Module Configurable I/O, page 49
Tank Control Module Configurable I/O, page
• Enter the unique node ID generated by the
Intelligent Paint Kitchen software for the control
module. See
Configure Each Station, page
See the E-Flo DC Control Module Kit manual 3A2527
or the Tank Control Module Kit manual 3A5991
for complete warnings and operating instructions,
including how to use the keypad to access and
change the software settings.
Figure 46 Control Module Keypad and Display
46
and
48.
and
48.
Set Up Pump Control
and
Set Up
51.
64.
Key
Key
Key
Name
Name
Name
Function
Function
Function
Toggle
Toggle between Run screens
and Setup screens.
Error
Clear alarm after cause has
Reset
been fixed. When there is no
alarm to clear, this key sets
the active pump's profile to
Stop. Also used to cancel data
entered and return to original
data.
Up Ar-
Move between screens or fields
row-
on a screen, highlight data
/Down
to change, or to increase or
Arrow
decrease the digits in a field.
Enter
Activate a field for editing or
accept the highlighted selection
on a menu.
Enter
Highlight data that can be
Screen
edited. Also can change the
function of the Up/Down arrows
so they move between data
fields on the screen, rather than
between screens.
Exit
Exit data editing.
Screen