Timers

1.2.7 User Codes

Number of User
Codes
User Code Attributes

1.2.8 Central Monitoring Options

Telephone Numbers
Communication
Protocols
Group Reporting to
CMS
Content Types for
Contact ID & SMS
Telephone Line
Monitoring
Digital Communicator

1.2.9 Other

Software Support
Memory Event Log
When a new device has been installed, it must be addressed and programmed into the
EURO system via Engineers Mode, the device will only then be seen when you exit
Engineers mode to save all the data to the NVM.
Page: 8
Entry Time, Exit Time, Bell Time, Confirm Time, Bell Delay, Strobe
Time, Re-Arm No, AC Signal Delay, Speaker, Final Exit delay, Double
Knock, Pre-Alarm, Line Fault, Arm Fail, Guard Code Alarm, Fire Bell
Time, Input NAT days, Input NAT Hours, Service Time
500 User Codes, 20 Duress Codes.
User Type, Partitions, Arm Options, Flexi Arm
4 primary numbers and 4 auxillary
Fast Format, SIA Level 1, SIA DK, Contact ID, SMS
Redials, Time Out, Stop on Success, Test Calls, Low Battery Report.
Arm, Disarm, Special Disarm, Arm Fail, Alerts, First Alarm, Alarm
Silenced, Confirmed, Lo Tech Faults, High Tech Faults, System
Changes/Resets, Manager Info, Engineer Info, Access Control Alarm,
Access Control Info, Access Control Ref, Special Log Switcher On, Off,
Special Log Other On, Off, Shunt/Sub-partition Set, Unset, Alarm, Walk
Test, Restores, Mains Fail, Duress, Emergency, Input Status, Aborts
Yes
Analogue Line and Digi Modem Card.
UDL Programming software.
Equipment needed:
Direct Dial: PCX RS232 lead
Remotely: Modem
3000

RINS869-8