Pyronix Enforcer V10 User Manual

Pyronix Enforcer V10 User Manual

Wireless alarm system

Advertisement

Wireless Alarm System
User Guide
Alarm Panel
Time
10:09 c
RINS1902
Document SAP: 102015108-03

Advertisement

Table of Contents
loading

Summary of Contents for Pyronix Enforcer V10

  • Page 1 Wireless Alarm System User Guide Alarm Panel Time 10:09 c RINS1902 Document SAP: 102015108-03...
  • Page 2: Table Of Contents

    Contents ProControl+ Setting Devices The Wireless Panel Keypad Wireless Keyfobs Locking the Keyfob Setting the System Using a PIN Code or Proximity Tag Using the Wireless Keyfob Unsetting the System Using a PIN Code or Proximity Tag Using the Wireless Keyfob Unsetting after an Alarm Using a PIN Code or Proximity Tag Using the Wireless Keyfob...
  • Page 3 ProControl+ Smart Device Application Basic Controls Connecting to the Panel Intruder Alarm Homescreen Advanced Controls History Setting/Unsetting Logs Installation Information Engineer Information Input Table Users Standard Users Guard, Duress and Dial Back Users Notes Extended User Guide Enforcer V10 User Guide...
  • Page 4: Procontrol

    Control appliances such as lights, garage doors, gates and blinds All using an encrypted, highly secure system, for extra peace AES-256 Encryption of mind that your family and home is safe and secure https://play.google.com/store/apps/ https://apple.co/2N4DF51 details?id=com.mcu.Pyronix&hl=en Enforcer V!0 User Guide...
  • Page 5: Setting Devices

    All four buttons on the keyfob may be locked so that any accidental presses will not affect your wireless alarm system. For example, this protects the buttons from being pressed accidentally if a keyfob is in someone’s pocket. 5 seconds 5 seconds Enforcer V10 User Guide...
  • Page 6: Setting The System

    Setting the System Using a PIN Code or Proximity Tag Enter a valid PIN code or present a valid tag to the Enter Your Code symbol as shown. [******] Enter the area you wish to set and press f. Set Areas? ‘Please wait setting wireless’...
  • Page 7: Unsetting The System

    [******] The alarm symbol will flash indicating there has Alarm Silenced been an alarm activation and the keypad will Lounge display which input has activated. Alarm Panel Press h to reset the system. Time 10:09 c Enforcer V10 User Guide...
  • Page 8: Using The Wireless Keyfob

    Using the Wireless Keyfob To unset via a keyfob. Press . <2 seconds The keyfob LED will start to flash green indicating that the system has unset. Resetting the system after an alarm can only be done at the keypad. Please note: Unsetting with a keyfob will only be allowed if your engineer has enabled this.
  • Page 9: Advanced Functions

    2 Key HU time period can be altered by your engineer). Please note: The keyfob can also be programmed to initiate a hold up alarm. All hold up alarms including duress codes must be enabled by the engineer. Enforcer V10 User Guide...
  • Page 10: Master Manager Mode Overview

    Master Manager Mode Overview The Master Manager Menu has the following functions: Please note: The options visible will depend on which modem is installed in the panel. Set Date and Time Programs the date and time. Operate User Outputs Activates/deactivates user automation outputs that are used to remotely activate devices, such as electronic gates &...
  • Page 11: Entering Master Manager Mode

    Exiting Master Manager Mode Press b or h keys to scroll through until ‘EXIT MANAGER MODE?’ is displayed. Press f. EXIT MANAGER MODE? Or, when a main menu item is displayed (capital letters) press a. Enforcer V10 User Guide...
  • Page 12: Master Manager Mode Options

    Master Manager Mode Options Set Time and Date Press b or h to scroll to ‘SET DATE & TIME?’ . SET DATE & TIME? Press f. Enter the year. Year (00-99) [18] Press f. Enter the month. Month (01-12) [09] Press f.
  • Page 13: Edit Users

    If a keyfob is programmed, the 'User Name' will be displayed on the keypad. User Name Enter the user name. Press f. Press [ or ] to choose the button to program. Select Button Lock Press f. Enforcer V10 User Guide...
  • Page 14: Deleting A User

    Press [ or ] to choose the action assigned to Button Action[2] Set Area the button. Press f. Please note: The following screens will not be displayed if you have programmed a wireless keyfob. Press [ or ] to choose between 'User' or User Type User 'Manager' .
  • Page 15: Change Master Manager Code

    LCD screen. Press h to program the wireless Setup with WI-FI Device network manually. ‘SSID?’ will now be displayed, press f and SSID? enter the SSID (name of the wireless network). Press f to return to ‘SSID?’ . Enforcer V10 User Guide...
  • Page 16: Procontrol+ Smart Device Application

    Press h and the LCD will change to ‘Password?’ Press f and enter the password Password? for the wireless network. Press f to return to ‘Password?’ . Press h and the panel will display the Wi-Fi signal strength. Signal Strength Please note: This needs to be 11 or above Press f and the panel will return to ‘WI-FI WI-FI SETUP?
  • Page 17: Intruder Alarm Homescreen

    Please note: If there has been alarm event, the red padlock will appear as a red bell instead. To unset, tap the red bell and it will return to a green padlock. Enforcer V10 User Guide...
  • Page 18: Advanced Controls

    Advanced Controls History Tap the control panel settings icon in the top right corner. A menu for the control panel will be shown. From this page select ‘History’ . Scroll up and down to see the history of events. To go back to the control panel settings page, click in the top left corner.
  • Page 19: Setting/Unsetting Logs

    A menu for the control panel will be shown. From this page select ‘Arming/Disarming Logs’ . This screen shows you the last time each area was set and unset. To go back to the control panel settings page, click in the top left corner. Enforcer V10 User Guide...
  • Page 20: Installation Information

    Installation Information Engineer Information Alarm Company Date of Installation Site Reference Engineer Name Engineer Contact Number Installed to Grade Environmental Class Input Table Input No. Input Name Input No. Input Name Enforcer V!0 User Guide...
  • Page 21: Users

    Please note: Users 15 to 20 are considered special users and can send specific events from the PyronixCloud. Please ask you engineer for more details. Guard, Duress and Dial Back Users User No. User Name User Areas Guard, Duress or Dial Back Enforcer V10 User Guide...
  • Page 22: Notes

    Notes Enforcer V!0 User Guide...
  • Page 23: Extended User Guide

    The Complete User Guide also includes: • An extended input table • An extended user table The Extended User Guide can be viewed and downloaded by scanning the below QR code or going to the link below the code. https://bit.ly/2pdjBQg Enforcer V10 User Guide...