3.6 Set / Unset System

Setting and unsetting the system can be done using the Engineer code.
1. Enter the Engineer code (default 1111).
2. Press if any faults appear.
3. 'SET/UNSET SYSTEM' is displayed.
4. Press .
5. Select the areas to set. Press .
6. The setting period will begin.
7. Once the timer expires, and a beep is heard, the Enforcer
32-WE is set.
8. To unset, enter the engineer code again.

3.7 Forced Arm On Inputs

The 'Force Arm On Inputs' function enables two nominated inputs on the Enforcer 32-WE to be set.
Either input can be triggered to allow real life signalling or alarm testing. This function is useful when
a building is full of people and these tests are needed.
NOTE 1: The system will give the correct signalling response to the Setting, and any resulting alarm.
NOTE 2: If the system has been set by any other code, the Engineer code will not unset it.
1. Enter the Engineer code (default 1111).
2. Press if any faults appear.
3. 'SET/UNSET SYSTEM' is displayed.
4. Press .
5. 'FORCE ARM ON 1st INPUT' is displayed.
6. Enter the 1st input that is to be active. Press .
7. Enter the 2nd input that is to be active. Press .
8. Select the areas to set. Press .
9. The setting period will begin
10. Once the timer expires, and a beep is heard, the
Enforcer 32-WE is set and the 2 inputs chosen will be
active.
11. To unset, enter the engineer code again.
Enforcer Programming Manual
Page: 8
SET / UNSET
SYSTEM?
SET AREAS
[A
Setting
[007]
Full Set
FORCE ARM ON 1st
INPUT?
[01]
FORCE ARM ON 2nd
INPUT?
[01]
SET AREAS
[A
]
]