136
Password level too low
This error is displayed when the user
attempts to switch to a page but does
not have the required password level. To
remedy: Log on (refer to "General menu
pages" in the handbook).
140
No printer program available
No printer program found. To remedy:
Load program.
141
Printer error (Error number)
An error has been detected during
transmission. To remedy: 1. Stop print
job, 2. Acknowledge error, 3. Check
connection, 4. Start print job again.
142
No paper in printer
A print job was started. Printer indicates
there is no paper. To remedy: Put paper
in printer.
Section 12
Page 18
150
Internal error (Error number)
This is an internal error which cannot be
caused by existing commands.
Potential errors: Er_[150] = 1
The command interpreter has received
an ID status which is not activated.
Potential errors: Er_[150] = 2nd
command has not been acknowledged.
To remedy: Deactivate the main switch
at the control cabinet and switch back on
after a few seconds. You can now
acknowledge the error. Look for potential
causes of the error in the token program.
Contact Battenfeld Customer Services.
151
Internal error (Error number)
Too many commands have been
entered for processing. To remedy:
Deactivate the main switch at the control
cabinet and switch back on after a few
seconds. You can now acknowledge the
error. Look for potential causes of the
error in the token program.
Contact Battenfeld Customer Services.
152
Data saving/loading error. Cause: An
error has occurred when loading or
saving data. To remedy: Load/Save the
data again.