Battenfeld UNIROB R10S User Manual page 144

Table of Contents

Advertisement

122
Lock area: No mould area available.
Cause: No mould area (Lock area 1)
entered.
To remedy: Enter Lock area 1 (refer to
"Service pages" in the handbook).
123
No Service parameters available
Cause: A cold start was carried out on
the RPS. This can occur when the
system is updated or when new
software is installed.
To remedy: Load service data on the
Data management menu page. (refer to
"General menu pages" in the handbook)
124
Controller not ready
The ACOPOS servo boosters are not
ready for operation. Causes: No power
supply (none of the 3 ACOPOS LEDs is
illuminated), no CAN connection (red
LED on ACOPOS servo booster
flashing).
To remedy: Check wiring.
Section 12
Page 16
125
CNC error (refer to the controller error
page for further details)
An error has occurred in the CNC
program. To determine the exact cause
please switch to the controller error
page.
126
Controller error (refer to the controller
error page for further details)
An error has occurred at the ACOPOS
servo booster. To determine the exact
cause please switch to the controller
error page.
127
Controller warning
A warning signal has been sent out by
the ACOPOS servo booster. To
determine the exact cause please
switch to the controller error page.
130 Language not available (Language
number)
The specified language is not available
or there is no ACOPOS error text
module.
Contact Battenfeld Customer Services if
the required language is not available.
Alarm list
A: R104GB12A.PMD
B: R104DE12A.PMD
E: 010404 / TCS
G: 150404 / T. Wenger

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Battenfeld UNIROB R10S

This manual is also suitable for:

Unirob b4Unilog b4

Table of Contents