Level
IN
Description
Use Program 25-07 : System Timers for VRS/DISA to set the value for the system timers which
affect DID and DISA. Refer to the following chart for a description of each option, its range and default
setting.
Input Data
Item
No.
01
VRS/DISA Dial Tone Time
After answering a DISA trunk, the system
waits this time for the caller to dial the first digit
of the DISA password. If the caller fails to dial
during this time, the system drops the call.
02
VRS/DISA No Answer Time
A VRS/DISA caller can ring an extension for
this time before the system sets the call as a
Ring No Answer. After this time expires, the
call follows the programmed Ring No Answer
routing (set in Program 25-03 and 25-04).
03
Disconnect after VRS/DISA retransfer to
IRG
From DISA trunk, when the call may go to
Incoming Ring Group of PRG25-03/25-04.
This setting determines how long the call is
ringing in the IRG.
04
Calling Time to Automatic Answering Tele-
phone Set
Set the answering waiting time of the auto-
matic answering extension when an incoming
DID trunk call is received.
05
Duration Time for Guidance Message by
Automatic Answering Telephone Set
Set the announcement time of the automatic
answering extension after which an incoming
DID trunk caller is disconnected.
07
Long Conversation Warning Tone Time
Determine the time a DISA caller or any trunk-
to-trunk (such as Tandem Trunking)
conversation can talk before the Long Conver-
sation tone is heard.
08
Long Conversation Disconnect Time
This time determines how long the system
waits before disconnecting a DISA caller or
any trunk-to-trunk (such as Tandem Trunking)
conversation call after the Long Conversation
tone is heard.
09
DISA Internal Paging Time
This is the maximum length of an Internal
Page placed by a DISA caller. If the Page
continues longer than this time, the system
terminates the DISA call.
10
DISA External Paging Time
This is the maximum length of an External
Page placed by a DISA caller. If the Page
continues longer than this time, the system
terminates the DISA call.
Programming Manual
Program 25 : VRS/DISA Setup

25-07 : System Timers for VRS/DISA

I
e t
m
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
0~64800 (sec)
n I
p
t u
D
a
a t
D
e
a f
u
10
10
60
10
10
30
15
30
30
SL1000
Related Pro-
t l
gram
25-04
25-04
20-31-17
20-31-18
14-01-25
20-28-01
20-28-02
20-28-03
20-31-19
14-01-25
20-28-01
20-28-02
20-28-03
20-31-21
20-31-22
2-263