Issue 0.1

21-13 : ISDN Calling Party Number Setup for Extensions

Level
IN
Description
Use Program 21-13 : ISDN Calling Party Number Setup for Extensions to assign each extension a
Calling Party Number (maximum 16 digits per entry). The calling number is the subscriber number of
the dial-in number. When a call is made by an extension which does not have an Extension Calling
Number assigned (Program 21-13), the system sends the calling number for the ISDN trunk defined in
Program 21-12.
If a Calling Party Number is assigned in both Programs 21-12 and 21-13, the system sends the data in
Program 21-13.
Input Data
Extension Number
Item No.
01
Conditions
None
Feature Cross Reference
ISDN Compatibility
Programming Manual
Program 21 : Outgoing Call Setup
Calling Party Number Data
0~9,
, # (Max. 16 digits)
*
Maximum four digits
Default
No setting