E1 Trunk Timer Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-13 : E1 Trunk Timer Setup to define the basic timer setting of E1 Trunk.
Input Data
Trunk Port Number
Item
Name
01
Loop Current Detection Time (Loop)
02
Clear Signal (Open Loop) Detection
Time
03
Transmit Clear Signal Time for Forced
Release
04
Receive DP Inter-digit min. Time
16
Pause Time
17
Pulse Dial Break Time
18
Pulse Dial Make Time
19
Pulse Dial Inter-digit Time
20
Receive DP Make min Time
21
Receive DP Make max Time
22
Receive DP Break min Time
23
Receive DP Break max Time
24
Transmit Answer duration Time
25
Transmit Double Answer duration Time
26
Receive Answer min Time
27
Receive Answer max Time
28
Receive Double Answer min Time
29
Receive Double Answer max Time
30
Transmit Seizure Acknowledge duration
Time
31
Receive Seizure Acknowledge min Time 1~255 (4ms ~ 1020ms)
Programming Manual

81-13 : E1 Trunk Timer Setup

1~126
Input Data
1~255 (16ms ~ 4080ms)
1~255 (16ms ~ 4080ms)
1~255 (16ms ~ 4080ms)
1~255 (4ms ~ 1020ms)
1~255 (64ms ~ 16320ms)
1~255 (4ms ~ 1020ms)
1~255 (4ms ~ 1020ms)
1~255 (16ms ~ 4080ms)
1~255 (4ms ~ 1020ms)
1~255 (4ms ~ 1020ms)
1~255 (4ms ~ 1020ms)
1~255 (4ms ~ 1020ms)
1~255 (8ms ~ 2040ms)
1~255 (64ms ~ 16320ms)
1~255 (8ms ~ 2040ms)
1~255 (8ms ~ 2040ms)
1~255 (64ms ~ 16320ms)
1~255 (64ms ~ 16320ms)
1~255 (4ms ~ 1020ms)
SL1000
Program
81
Default
3
48ms
50
800ms
50
800ms
125
500sec
47
3008ms
15
60ms
10
40ms
50
800ms
3
12ms
19
76ms
5
20ms
26
104ms
38
304ms
32
2048ms
25
200ms
50
400ms
24
1536ms
47
3008ms
25
100ms
25
100ms
2-431

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents