Level
IN
Description
Use Program 25-07 : System Timers for VRS/DISA to set the value for the system timers which af-
Program
fect DID and DISA. Refer to the following chart for a description of each option, its range and default
setting.
25
Input Data
Item
No.
01
VRS/DISA Dial Tone Time
After answering a DISA trunk, the system
waits this time for the caller to dial the first digit
of the DISA password. If the caller fails to dial
during this time, the system drops the call.
02
VRS/DISA No Answer Time
A VRS/DISA caller can ring an extension for
this time before the system sets the call as a
Ring No Answer. After this time expires, the
call follows the programmed Ring No Answer
routing (set in Programs 25-03 and 25-04).
03
Disconnect after VRS/DISA retransfer to
IRG
From DISA trunk, when the call may go to In-
coming Ring Group of Programs 25-03 and
25-04. This setting determines how long the
call is ringing in the IRG.
04
Calling Time to Automatic Answering Tele-
phone Set
Set the answering waiting time of the auto-
matic answering extension when an incoming
DID trunk call is received.
05
Duration Time for Guidance Message by
Automatic Answering Telephone Set
Set the announcement time of the automatic
answering extension after which an incoming
DID trunk caller is disconnected.
07
Long Conversation Warning Tone Time
Determine the time a DISA caller or any trunk-
to-trunk (such as Tandem Trunking) conversa-
tion can talk before the Long Conversation
tone is heard.
08
Long Conversation Disconnect Time
This time determines how long the system
waits before disconnecting a DISA caller or
any trunk-to-trunk (such as Tandem Trunking)
conversation call after the Long Conversation
tone is heard.
09
DISA Internal Paging Time
This is the maximum length of an Internal
Page placed by a DISA caller. If the Page con-
tinues longer than this time, the system termi-
nates the DISA call.
10
DISA External Paging Time
This is the maximum length of an External
Page placed by a DISA caller. If the Page con-
tinues longer than this time, the system termi-
nates the DISA call.
2-284
Program 25 : VRS/DISA Setup

25-07 : System Timers for VRS/DISA

Item
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
0 ~ 64800 seconds
Input Data
Default
10 seconds
10 seconds
60 seconds
10 seconds
10 seconds
30 seconds
15 seconds
30 seconds
30 seconds
Program 25 : VRS/DISA Setup
ISSUE 1.0
Related Pro-
gram
25-04
25-04
20-31-17
20-31-18
14-01-25
20-28-01
20-28-02
20-28-03
20-31-19
14-01-25
20-28-01
20-28-02
20-28-03
20-31-21
20-31-22

Hide quick links: