NEC SL1000 Programming Manual page 402

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
Answer Table 1
Program
47
Conditions
None
Feature Cross Reference
None
2-382
Type 3 (Date) Example
Answer Schedule 1
Answer Schedule 1 is a Range of
Days schedule that starts schedule
that runs every day from 8:30AM to
5:00PM.
Answer Schedule 2
Answer Schedule 2 is a Date
schedule that runs only on Christmas
day from 8:30AM to 5:00PM.
47-12-01: Entry01 Schedule Type = 2
47-12-02: Entry01 MB Ctg = 3
47-12-02: Entry01 MB Num = 1
47-12-03: Entry01 Day = 1 (Entry does not matter)
47-12-04: Entry01 Start Day = 1 (Sunday)
47-12-05: Entry01 End Day = 1 (Sunday)
47-12-06: Entry01 Date (MMDD) = 0000 (Entry does not
matter)
47-12-07: Entry01 Start Time = 0830 (8:30AM)
47-12-08: Entry01 End Time = 1700 (5:00PM)
47-12-01: Entry01 Schedule Type = 3
47-12-02: Entry01 MB Ctg = 3
47-12-02: Entry01 MB Num = 9
47-12-03: Entry01 Day = 1 (Entry does not matter)
47-12-04: Entry01 Start Day = 1 (Entry does not matter)
47-12-05: Entry01 End Day = 1 (Entry does not matter)
47-12-06: Entry01 Date (MMDD) = 1225 (December 25,
Christmas day)
47-12-07: Entry01 Start Time = 0830 (8:30AM)
47-12-08: Entry01 End Time = 1700 (5:00PM)