E1 Trunk Basic Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Level
IN
Description
Use Program 34-11 : E1 Trunk Basic Setup to define the basic setting of each E1 Trunk.
Input Data
Trunk Port Number
Item No.
Name
01
E1 Trunk Type
Use this option to specify the
E1Signal type(0-8). Set this option for
compatibility with the connected
telco.
02
MFC Dialing Type
Use this option to specify the MFC
Dialing Type. The following table
shows the available MFC Dialing
Type choices, By default, this option
is 0 (MFC Dialing not used).
03
MFC Group B
Use this option to enable(1) or
disable(0) the MFC Dialing Group B
supervisory signaling. Since not all
central offices provide Group B
signaling, set this option for compat-
ibility with the connected telco. By
default, this option is Disable(0).
04
Expected Number of MFC Digits
Use this option to specify the number
of digits in the ANI number. This is
required for ANI since delimiters do
not mark the beginning and end of
the data string. The system must
know how many digits of incoming
ANI Caller ID data to interpret.
Conditions
After set PRG34-11-01, the E1 card needs resets.
Feature Cross Reference
• E1 Trunking
Programming Manual
Program 34 : Tie Line Setup

34-11 : E1 Trunk Basic Setup

Input Data
0 = Standard Trunk
1 = Argentine Pulsed Clear Back Trunk
2 = Argentine Pulsed Answer Trunk
3 = Brazil With seizure acknowledge Trunk
4 = Brazil Without seizure acknowledge Trunk
5 = Brazil E&M Signal A(Idle=0) Trunk
6 = Brazil E&M Signal A(Idle=1) Trunk
7 = Brazil E&M Signal B(Idle=0) Trunk
8 = Brazil Code for collect call blocking Trunk
0 = MFC Dialing not used
1 = NEC Standard
2 = Argentina
3 = Brazil
4 = Chile
5 = Colombia
6 = Mexico
7 = Venezuela
0 = Disable
1 = Enable
0~20
SL1000
1~126
Default
0
0
0
7
2-319
Program
34

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents