Isdn Bri & Pri Layer3 (S-Point) Timer Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Program 82 : Basic Hardware Setup for
82-06 : ISDN BRI & PRI Layer3 (S-point) Timer Setup
Level
IN
Description
Use Program 82-06 : ISDN BRI&PRI Layer3 (S-Point) Timer Setup to set the basic timer for the
layer 3 of ISDN BRI & PRI S-Point.
Input Data
layer3 Timer Type No.
Item No.
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
Conditions
None
Feature Cross Reference
None
Programming Manual
Item
T301
T302
T303
T304
T305
T306
T307
T308
T309
T310
T312
T313
T314
T316
T317
T318
T319
T320
T321
T322
1~ 5
Input Data
0, 180~254(sec)
1~254(sec)
1~254(sec)
0~254(sec)
1~254(sec)
0~254(sec)
1~254(sec)
1~254(sec)
1~254(sec)
0~180(sec)
1~254(sec)
1~254(sec)
1~254(sec)
(T317 + 1) ~254(sec)
1~(T316-1)(sec)
1~254(sec)
1~254(sec)
1~254(sec)
1~254(sec)
1~254(sec)
SL1000
Extension
Default
180(sec)
10(sec)
4(sec)
20(sec)
30(sec)
30(sec)
180(sec)
4(sec)
90(sec)
30(sec)
6(sec)
4(sec)
4(sec)
120(sec)
60(sec)
4(sec)
4(sec)
30(sec)
30(sec)
4(sec)
2-439
Program
82

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents