Isdn Bri & Pri Layer 3 (T-Point) Timer Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
Program 81 : Basic Hardware Setup for Trunk
Level
IN
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the various basic
timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Program
Input Data
81
Item No.
01
02
03
04
05
06
07
08
09
10
11
12
13
2-420
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Layer 3 Timer Type Number
Item
T301
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
ALERT message is received.
T302
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is sent. Timer is also restarted
when INFO is received.
T303
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent.
T304
Specifies the timer value in 1/100ths of a
second of the timer to be started when the
SETUP ACK is received. Timer is also re-
started when INFO is received.
T305
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC without progress No. 8 is sent.
T306
Specifies the timer value in 1/100ths of a
second of the timer to be started when
DISC with progress indicator No. 8 is sent.
This timer is valid for Network side use
only.
T307
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SUSPEND ACK is sent. This timer is valid
only for Network side use only.
T308
Specifies the timer value in 1/100ths of a
second of the timer to be started when
REL is sent.
T309
Specifies the timer value in 1/100ths of a
second upon data link disconnection.
T310
Specifies the timer value in 1/100ths of a
second of the timer to be started when
CALL PROC is sent.
T312
Specifies the timer value in 1/100ths of a
second of the timer to be started when
SETUP is sent or re-sent on broadcast
data link. This timer is only valid for Net-
work side use only.
T313
Specifies the timer value in 1/100ths of a
second of the timer to be started when
connection request is sent. Valid range 1 ~
4 seconds in 1 second increments. Value
of 0 indicates timer not used.
T314
Specifies the timer value in 1/100ths of a
second of the timer to be started when
message segment is received.
Description
0, 180~254 (sec)
1~254 (sec)
1~254 (sec)
0~254 (sec)
1~254 (sec)
0~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
0~180 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
Program 81 : Basic Hardware Setup for Trunk
Issue 0.1
1~5
Input Data
Default
180 (sec)
15 (sec)
4 (sec)
30 (sec)
30 (sec)
30 (sec)
180 (sec)
4 (sec)
90 (sec)
180 (sec)
6 (sec)
4 (sec)
4 (sec)