Program 81 : Basic Hardware Setup For Trunk; Cot Initial Data Setup - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000

Program 81 : Basic Hardware Setup for Trunk

Level
IN
Description
Use Program 81-01 : COT Initial Data Setup to define the various basic data parameters for the COT
Program
Unit.
81
Input Data
I
e t
m
N
. o
01
02
03
04
05
06
07
08
09
10
11
14
15
16
17
20
21
22
23
27
2-416
I
e t
m
PCM Encoding Method Specification
Loop Current Detection Time
Clear Signal (Open Loop) Detection Time
Ringing Signal Detection Minimum Time
Single Ringing Detection Minimum Time
Double Ringing Detection Minimum Off
Time
Double Ringing Detection Maximum Off
Time
Ringing Signal not Detection Minimum
Time Ringing Signal Stop Detection Time
Continuous Ringing Minimum Time
Continuous Ringing Maximum Time
Hook Flash 1 Time
Hook Flash 2 Time
Pause Time
PFT Idle Detection Time
Loop Reverse Detect Minimum Time
Loop Reverse Detect Maximum Time
Loop Disconnect Detect Minimum Time
Loop Disconnect Detect Maximum Time
Dial Pulse Break Time (10pps)

81-01 : COT Initial Data Setup

n I
p
t u
D
a
a t
0 = μ-law
1 = A-law
1~255
(10~2550 ms)
1~255
(5~1275 ms)
1~255
(10~2550 ms)
0~255
(0, 10~2550 ms)
0~255
(0, 10~2550 ms)
0~255
(0, 10~2550 ms)
1~255
(10~2550 ms)
1~255
(100~25500 ms)
0~255
(0, 10~2550 ms)
0~255
(0, 10~2550 ms)
1~255
(10~2550 ms)
1~255
(100~25500 ms)
1~255
(100~25500 ms)
1~255
(100~25500 ms)
1~255
(10~2550 ms)
1~255
(10~2550 ms)
1~255
(10~2550 ms)
1~255
(10~2550 ms)
1~255
(5~1275 ms)
Program 81 : Basic Hardware Setup for Trunk
Issue 0.1
D
e
a f
u
t l
1 (A-law)
60 (600 ms)
59 (295 ms)
10 (100 ms)
66 (660 ms)
10 (100 ms)
40 (400 ms)
70 (700 ms)
50 (5000 ms)
30 (300 ms)
70 (700 ms)
80 (800 ms)
25 (2500 ms)
30 (3000 ms)
30 (3000 ms)
10 (100 ms)
86 (860 ms)
50 (500 ms)
70 (700 ms)
13 (65 ms)