Issue 0.1
Alarm
Re-
Type
Name
No.
port
4
2
0
PKG S/W
Download
Error
6
0
0
Blocking
8
1
0
RAM
Backup
Battery
Error
Programming Manual
Content of Alarm
Cause
The unit program
1 The pack-
could not be down-
age
loaded normally. The
unit could not able to
software is
be started normally.
not stored
in the
down-
loaded
USB
memory.
2 The stored
package
software is
illegal-
.Package
information
that was
installed
before
remains.
The link of terminals
1 Terminal
connected with the
Break-
ESI package came
off.
down.
2 Faulty wir-
ing and
wiring ter-
mination.
3 External
noise.
4 ESI pack-
age
Break-
down. .
RAM backup battery
on the CPU unit is
unplugged or
defective.
Action
Recovery
Please ex-
1 Delete slot
change
information
units,
though it is
that corre-
likely to re-
sponds by
store by
PRG90-05-
mounting
the unit
01 to delete
again.
package in-
When the
formation that
unit pro-
gram is
was installed
normally
before.
down-
loaded, the
2 There is a
error is
possibility
recovered.
that the unit
program is
broken
though an
external fac-
tor of the
noise etc. is
thought.
3 Please load
into the USB
memory and
try again
when you
back up the
unit program.
4 PleaseCheck
with maker
on uncertain
points.
Confirm the terminal
The error is
connected with same
recovered
ESI. If they work nor-
when con-
mally, confirm the
necting or
breakdown or the wir-
exchanging
ing for the terminal.
it.
Exchange the
terminal that doesn't
work and the working
terminal, and confirm
external factor of the
noise etc. is thought.
Please reconfirm
wiring and the instal-
lation,etc.Please
inquire of the manu-
facturer when the
problem occurs after
it confirms it.
Check the battery
The error is
connector. If it is con-
recovered
nected correctly,
once the
replace the battery.
battery is
replaced.
SL1000
Alarm
Sta-
tus
ERR
REC
Program
90
ERR
REC
ERR
REC
2-499