System Options For Caller Id - NEC SL1000 Programming Manual

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

Issue 0.1
Level
IN
Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID
feature.
Input Data
Item No.
01
Caller ID Displaying Format(if displaying
digits are more than 12 digits)
02
Caller ID Wait Timer
When an incoming CO call is received, the
SL1000 starts the timer. It will wait the
programmed time for Caller ID information
from telco before connecting the CO call.
03
Caller ID Edit Mode
If Caller ID Edit Mode is disabled (0), no trunk
access code will be added to the Caller ID. If
this option is enabled (1), the trunk access
code entered in Program 10-02-05 will be
added to the beginning of the Caller ID.
04
Wait Facility IE Timer
This timer is used with ISDN trunks to deter-
mine how long the system waits for the Caller
ID name from the Telco.
05
Caller ID Sender Queing Time (Sender
Wait)
07
Long Distance Code
08
Area Code
Conditions
None
Feature Cross Reference
• Caller ID
Programming Manual
Program 20 : System Option Setup

20-19 : System Options for Caller ID

Item
0=First 10 digits (Upper)
1=Last 10 digits (Lower)
0-30 seconds
0 = off
1 = on
0~64800 seconds
0~64800 seconds
Up to two digits
Up to six digits
Input Data
SL1000
Program
20
Default
0
5
0
10
0
No setting
No setting
2-167