NEC SL1000 Programming Manual page 518

Hide thumbs Also See for SL1000:
Table of Contents

Advertisement

SL1000
Alarm
Type
No.
3
2
Program
90
2-498
Re-
Name
Content of Alarm
port
0
Connection
The error occurred
fault be-
when communicat-
tween CPU
ing with the
and other
package. When the
PKGs.
package is broken, it
recognizes it as a
communication fault.
Cause
Action
1 The unit is
1 Please insert
not com-
the unit firmly.
pletely
2 The power-
inserted.
supply
2 The power-
voltage must
supply
use another
voltage of
power supply
the system
when is in the
is outside
range of rat-
ratings.
ings or
measuring
3 The equip-
with the volt-
ment that
meter, and
generates
deviating
the noise in
from the
the same
rated range.
power sup-
ply system
3 Please use
as the
the power
power sup-
supply be-
ply origin of
sides the
the system
equipment
is con-
with the pos-
nected,
sibility of the
and it mal-
noise source.
functions
4 Please sepa-
because of
rate as much
the power
as possible
supply
and use a
noise.
main device
4 The equip-
from the
ment to
equipment by
which it is
which you
adjacent to
seem may
of a main
generate the
device, and
radiation
has put out
noise.
the radia-
5 Please
tion noise
ground the
exists, and
chassis
it malfunc-
correctly.
tions
because of
the radia-
tion noise.
5 The chas-
sis is not
properly
grounded.
Program 90 : Maintenance Program
Issue 0.1
Alarm
Sta-
Recovery
tus
When unit
ERR
is con-
REC
firmed, the
error is
recovered.