Item No.
07
Digital Pager Callback Number
(Pager CBack)
Use this option to set the Digital Pager Callback
Number portion of the Message Notification callout
number for a digital pager. This is the portion of the
callout number that is appended to the pager
service telephone number. Normally, this option
should be X
M#, where:
*
• X is the number of the extension that gener-
ated the notification.
is a visual delimiter (to make the pager
*
display easier to read).
• M is the number of new messages in the
extension mailbox.
• # is the digit normally used by the pager
service for positive disconnect.
08
Delay in Dialing Digital Pager Callback Number
(Pager Dial Delay)
Use this option to set the delay (0~99 seconds)
that occurs just before InMail dials the Digital
Pager Callback Number portion of the Message
Notification callout number for a digital pager. Set
this delay so the pager service has enough time to
connect to the digital pager before sending the
callback number. Your pager service may be able
to help you determine the best value for this option
(0~99 seconds). By default, this option is 9
seconds. When placing a digital pager notification,
the system: Seizes the trunk specified. Dials the
user-entered notification number (in Message +
OP + N).
Waits the 47-01-08: Delay in Dialing Digital
Pager Callback Number interval.
Dials the number entered in 47-01-07: Digital
Pager Callback Number.
The system assumes that the notification number
completes dialing approximately 4 seconds after
trunk seizure. This means that, by default, the
Digital Pager Callback Number is dialed into the
pager service about 13 seconds after trunk
seizure.
09
Wait Between Digital Pager Callout Attempts
(Notify Pager Intvl)
Use this option to set the minimum time (1~255
minutes) between unacknowledged or unanswered
digital pager Message Notification callouts. (A
subscriber acknowledges a digital pager notifica-
tion by logging onto their mailbox.) After this time
expires, InMail tries the callout again (for up to the
number of times set in 47-01-14: Number of
Callout Attempts).
If the system dials the callout number and the
pager service is busy, it retries the number in one
minute.
10
Wait Between Non-Pager Callout Attempts
(Notify N-Pgr Intvl)
Use this option to set the minimum time (1~255
minutes) between non-pager Message Notification
callouts in which the destination answers, says
Hello, dials 1 to acknowledge and then enters the
wrong security code.
11
Wait Between Busy Non-Pager Callout At-
tempts
(Notify Busy Intvl)
Use this option to set how long InMail waits (1~255
minutes) after it dials a busy non-pager callout
destination, before retrying the callout number.
Programming Manual
Item
Digits
(12 maximum, using 0~9, # and
)
*
M (Number of messages -
entered by pressing LK1)
X (Extension number - entered
by pressing LK2)
InMail automatically replaces the
X command with the number of
the extension that initially
received the message.
0~99 (sec)
1~255 (min)
1~255 (min)
1~255 (min)
Input Data
Default
SL1000
X
M#
*
Program
47
30
15
20
15
2-355