Connecting Extensions

Connecting Extensions
Each 16DSTU PCB connects 16 digital extensions. Each 8ASTU PCB connects 8 analog extensions. Each
4ASTU PCB connects 4 analog extensions.
To connect extensions (Figure 3-1):
1.
Using Figure 2-12 Connecting Extensions on page 2-10 as a guide, insert the mod jacks into the appro-
priate connector on the PCB.
2.
Install a modular jack for each extension within 6 feet of the telephone's location.
3.
For each extension, run one-pair 24 AWG station cable from the cross-connect block to the modular jack.
4.
Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack.
5.
Back at the main equipment location, run one pair of cross-connect wire between the pins on the B
block and cross-connect block to complete the connection.
6.
Install bridging clips as required.
One-Pair
Cross Connect
Station
Block
DS2000 Hardware Manual
Section 3: Installing
Extensions and Trunks
YEL
BLU-WHT
Cross
Connect
RED
Block
25-Pair
Installation Cable
(P/N 80892)
Figure 3-1: Connecting Extensions
Connecting Extensions
You can also connect analog extensions to 2-OPX
Modules. Refer to Section 4, Optional Equipment.
BLK
WHT-BLU
GRN

Section 3: Installing Extensions and Trunks