7 Operation at Use of a PC
7.4 Value View and Evaluation
Select in the button choice Open/Save/Cancel  Save  Save As: see figure 7-7.
Select the file path.
Use the file name suggested in the File name: list box or enter a new file name with the displayed file
extension, for example *.pqd for files of the trend recorder
NOTE
The length of file names must not exceed 8 characters. Use only characters according to NOTE in Open Con-
figuration from File.
Click Save.
Close the button choice Download has completed..
Option: Multiple File Download
Preparation
If you want to use the Multiple File Download option, you have to make the following change once with the
Registry Editor of your computer:
Start  Search  regedit  regedit.exe  OK
The Registry Editor opens.
Find in the directory: [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Internet Explorer\ActiveX
Compatibility\{00000566-0000-0010-8000-00AA006D2EA4}] \Compatibility Flags
Click on Compatibility Flags and change the value to 0.
Figure 7-54
168
Changing the Compatibility Flag Value
.
SENTRON PAC5100/5200, 7KM5212/5412, Device Manual
E50417-H1040-C568-A1, Edition 03.2015