Vibration Suppression Control Setting (1) to (2) (B-15514 to 15515)

1
2
Outline
This screen is used to set the parameters necessary for the vibration suppression control.
Description
1.
Switches the Vibration suppression control setting screens. The screen of a light blue switch is the
screen which is currently being displayed.
2.
Selects the vibration suppression mode.
Only when selecting [3 inertia mode], Vibration suppression control 2 can be set.
3.
Displays the vibration suppression control image screen.
4.
Sets Vibration suppression control 1 (When B-15514 is displayed) or Vibration suppression control 2
(When B-15515 is displayed).
Selects one of [No setting], [Tuning], and [Manual setting].
When selecting Manual setting, each item can be set.
Touch the value to set the value.
to change the values a s follows .
Touch
Vibration frequency
Resonance frequency
Vib. freq. damping
Resonance freq. damping
Sets the command notch filter. Touch the switch of each item to display the f ollowing screen.
5.
Item
Frequency selection
Notch depth selection
Remarks
・ When the gain adjustment mode is [ Auto tuning mode 2 ], [ 2 gain adjustment mode 2 ], or [Manual mode],
the vibration suppression control setting can be set.
Parameter
Displays the Command Notch Filter (Frequency) screen.
Displays the Command Notch Filter (Notch Depth) screen.
31/128
Change amount
0.1
0.01
Displayed screen
BCN-P5999-1471-3c