LBC-4000 L-Band Up/Down Converter System
Appendix B
Force Backup
Use the drop-down menu to select Yes, and then click [Change] to force the
redundant unit into standby mode.
The last section on this page displays the read-only Online or Offline status for
each converter.
B.4 Redundancy Operations Using Serial Remote
Control
See Chapter 8. SERIAL INTERFACE OPERATION for detailed
information about using serial remote control commands and
queries.
The "FBU," "RED," and "SAM" remote commands and queries are provided for
LBC-4000 redundancy operation.
B.4.1
FBU (Force Backup Unit)
Command only. Use "FBU" to force switchover to the backup unit. Valid in
Manual redundancy mode only.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
FBU_
N/A
B.4.2
RED (Redundancy Mode)
Command or Query. Use "RED" to set or return the active redundancy mode.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
RED_
RED_
3 bytes,
alphabetic
Description of Arguments
Query
0 bytes
This command takes no arguments.
Description of Arguments
Query
Set or return in the form RED_yyy where:
yyy=ON (Redundancy is enabled) or OFF
(Redundancy is disabled)
B–8
MN/LBC4000.IOM
Revision 5
Target-to-Controller
Response
Command
Query
N/A
N/A
Target-to-Controller
Response
Command
Query
RED_
RED_