LBC-4000 L-Band Up/Down Converter System
Serial Interface Operation
8.3.3
ATT (Attenuation Level)
Command or query. Use "ATT" to set or return the attenuation level, in dB, in 0.1
dB steps.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
ATT_y_xx.xx
ATT_y_
alphanumeric
Command Example: <0001/ATT_A_+12.20{cr}
8.3.4
CAA (Clear All Alarms)
Command only. Use "CAA" to clear all stored alarms from the Target's events
log.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
CAA_xxx{cr}
N/A
Command Example: <0001/CAA_YES{cr}
Description of Arguments
Query
Set or return in the form ATT_y_xx.xx where:
7 bytes,
y=A (Conv A) or B (Conv B)
xx.xx=Valid attenuation level, in dB (0.1 dB step
size is factory default)
Description of Arguments
Query
3 bytes,
Set or return in the form CAA_xxx where:
alphabetic
xxx=YES
8–9
MN/LBC4000.IOM
Revision 5
Target-to-Controller
Response
Command
Query
ATT_y_xx.xx
ATT_y_ xx.xx
Target-to-Controller
Response
Command
Query
CAA_CLEARED
N/A
Need help?
Do you have a question about the MN/LBC4000.IOM and is the answer not in the manual?
Questions and answers