LBC-4000 L-Band Up/Down Converter System
Serial Interface Operation
Query Example:

8.3.41 TIM (Set RTC [Real-Time Clock] Time)

Command or Query. Use "TIM" to set or return the real-time clock time.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
TIM_
TIM_
8 bytes,
numeric
Command Example: <0001/TIM_23:12:59{cr}

8.3.42 VFD (Set Vacuum Fluorescent Display Brightness)

Command or Query. Use "VFD" to set or return the brightness level for the front
panel display.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
VFD_
VFD_
1 byte, numeric,
value 0 to 3
<0001/SSN_U{cr}
>0001/SSN_U_012345678{cr}{lf}
Description of Arguments
Query
Set or return the time, in military/from midnight
format, in the form TIM_hh:mm:ss where:
hh:=hours from 00 to 23
mm:=minutes, from 00 to 59
ss=seconds, from 00 to 59
(Sets time from midnight to 23 hours, 12 minutes, 59
seconds, or 11:12:59 PM)
Description of Arguments
Query
Set or return the vacuum fluorescent display
brightness in the form VFD_x where:
x=0 (100%), 1 (75%), 2 (50%), or 3 (25%)
8–24
MN/LBC4000.IOM
Revision 5
Target-to-Controller
Response
Command
Query
TIM_
TIM_hh:mm:ss
Target-to-Controller
Response
Command
Query
VFD_
VFD_x