LBC-4000 L-Band Up/Down Converter System
Appendix B
B.4
Redundancy Operations via Serial Remote Control
See Chapter 6. SERIAL‐BASED REMOTE PRODUCT MANAGEMENT for detailed
information about using Serial Remote Control commands and queries for remote
Redundancy configuration, operation, and monitoring.
The following remote commands and queries are available for LBC‐4000 Redundancy operation:
Parameter Type
Force Backup Unit
Redundancy Mode
Set Auto/Manual
Redundancy Mode
Command /
Query
(Note that all arguments are ASCII numeric codes between 48 and 57)
FBU
Command only.
Forces switchover to backup unit in Manual redundancy mode only in the form
FBU_
RED
Command or Query.
Used to set the chassis in redundancy mode or to query status of redundancy in
the form RED_xxx where:
xxx = ON (if redundancy is enabled) or
OFF(if redundancy is disabled)
SAM
Command or Query.
Used to set or get status of Redundancy to either Manual or Automatic mode in
the form SAM_x where:
x = a (if chassis is in Automatic Redundancy mode) or
m (if chassis is in Manual Redundancy mode)
Description of Arguments
B–8
Revision 4
MN/LBC4000.IOM
Need help?
Do you have a question about the LBC-4000 and is the answer not in the manual?
Questions and answers