LBC-4000 L-Band Up/Down Converter System
Appendix B
• REDUND Submenu – The selections here allow you to identify the
redundancy state and mode. SEE SECT. B.2.1.3 TO USE THIS SUBMENU IN
REDUNDANCY OPERATIONS.
• REFADJ Submenu – This screen allows you to adjust the reference
oscillator.
• SPECT-INV Submenu – The selections here allow you to set the Converter
A and Converter B spectral inversion to INVERTED or NORMAL.
B.2.1.3 (CONFIG:) REDUND (Redundancy)
Use the [][] arrow keys to select Mode, State, or F up. Press [ENT].
(CONFIG:) Redundancy  Mode
Use the [][] arrow keys to select Manual or Auto. Press [ENT].
Note that, if you attempt to access this menu and the Redundancy State is
Disabled, you will see this message:
CONFIG: Redundancy  State
Use the [][] arrow keys to select Disable or Enable. Press [ENT].
CONFIG: Redundancy  FrcBkup
Redundancy:
Mode
State
FrcBkup
Redundancy:
Control Mode = Manual
Not Available In
Current Mode
Redundancy Mode:
Control State = Enable
Config Manual Redundancy
Force Backup
B–5