LBC-4000 L-Band Up/Down Converter System
Firmware Update
• You download or otherwise have Comtech's latest firmware files and the
"CReflash" utility available on the User PC in an accessible temporary
folder.
5.4.2

Steps to "CReflash" Upload the Firmware Files

1) The "CReflash" utility is provided with the firmware download.
Serial-only (i.e., non-Ethernet) units must use this procedure.
2)
Do these steps:
1. From the temporary folder – Locate, and then double-click, the
"CReflash" filename or icon. The CReflash utility opens:
2. Enter your upload parameters information into CReflash:
a. Left-click in the "IP Address:" text box, and enter the default
Management IP Address.
b. Left-click in the "Local Filename:" text box. Then, click [Browse]
and navigate to the temporary folder created earlier. Click on the
firmware "bin" filename, and then click [Open]. The filename will
appear in the "Local Filename:" text box.
c. Make sure the drop-down list remains set to "bulk:".
d. Click [Start] to begin the upload process. If the information was
correctly entered into CReflash, the utility displays an animated
progress bar at the bottom of the window, along with a series of
messages:
• "Opening FTP"
• "Sending data file to modem:"
• "Writing FLASH: # of #"
5–12
MN/LBC4000.IOM
Revision 5