Comtech EF Data MN/LBC4000.IOM Installation And Operation Manual page 121

L-band up/down converter system
Table of Contents

Advertisement

LBC-4000 L-Band Up/Down Converter System
Ethernet Interface Operation
Parameter Status
Product identification (i.e., CID/AID, serial and model numbers), active firmware,
software image information, and other operational configuration information is
provided here.
Converter A / Converter B Status
This section identifies the converter installed in each module slot (BUC or BDC)
and each module's associated RF conversion band and frequency, attenuation
value, mute status, and online/offline status.
Converter A / B, PS (Power Supply) A / B, Monitor and Status
This section provides the current monitored value for each module (BUC or BDC),
including the RF/IF lockout status, operating voltages and temperatures. The
operating voltages for each power supply are also provided.
Note that:
1) Valid Converter A/Converter B LNA Current readings are provided only if
the pertinent LBC-4000 Down Converter (BDC) is optionally configured
with an LNA. These parameters otherwise display as N/A if the pertinent
converter is a BUC.
2) Valid Converter A/Converter B Forward RF Power readings are provided
only if the pertinent LBC-4000 up converter (BUC) is optionally configured
with the Power Monitor feature. These parameters otherwise display as
N/A if the pertinent converter is a BDC.
3) Valid Power Supply 2 and Local Switch Position information is provided
with redundant configurations only.
7–25
MN/LBC4000.IOM
Revision 5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lbc-4000Cd-mnlbc4000

Table of Contents