LBC-4000 L-Band Up/Down Converter System
Serial Interface Operation
8.3.9
CUS (Concise Utility Status)
Query only. Use "CUS" to return a summarized version of the utility status.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
N/A
CUS_
85 bytes,
numeric
8.3.10 DAT (Set RTC [Real-Time Clock] Date)
Command or Query. Use "DAT" to set or return the calendar date.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
DAT_
DAT_
8 bytes,
numeric
Command Example: <0001/DAT_04/25/16{cr} (Sets date as April 25, 2016)
8.3.11 FBU (Force Backup Unit)
Command only. Use "FBU" to force switchover to the backup unit. Valid in
Manual redundancy mode only.
Controller-to-Target
Arguments for
Instruction Code and Qualifier
Command or
Response to
Command
Query
FBU_
N/A
Description of Arguments
Query
Returns utility status in the form
"CUS_hh:mm:ssmm/dd/yyabcsssfffffffggggggghhh
hhhh{cr}{lf}" where:
hh:mm:ss=TIME
mm/dd/yy=DATE
a=X (reserved for future use)
b=X (reserved for future use)
c=display brightness (0=100%, 1=75%, 2=50%,
3=25%)
sss=screen saver time in minutes
fffffff=BULK firmware
ggggggg=M&C firmware
hhhhhhh=FPGA firmware
Description of Arguments
Query
Returns info in the form DAT_mm/dd/yy where:
mm=month of the year, from 01 to 12
dd=day of the month, from 01 to 31
yy=year, from 00 to 96 (2000 to 2096)
Description of Arguments
Query
0 bytes
This command takes no arguments.
8–12
MN/LBC4000.IOM
Revision 5
Target-to-Controller
Response
Command
Query
N/A
CUS_t...h
Target-to-Controller
Response
Command
Query
DAT_
DAT_mm/dd/
yy
Target-to-Controller
Response
Command
Query
N/A
N/A
Need help?
Do you have a question about the MN/LBC4000.IOM and is the answer not in the manual?
Questions and answers