8.3 Copy device memory data

8.3 Copy device memory data
Solution and Benefit
The data in file registers and data registers can be copied between different CPU types, so that the
existing data can be used easily.
(1) Example of copy operation
The following is an example of operation to copy file register data between different CPU types.
Step 1: Display the device memory R0 in the existing ACPU program file using GX Developer, drag
the mouse to select the range to be copied into QCPU after replacement, and store the
data in the copy buffer.
To store, select "GX Developer edit menu" -> "Copy" or "Ctrl+C."
Step 2: Start up GX Developer separately from the existing ACPU program file, display the device
memory R0, and specify the top position in QCPU into which the data will be pasted.