● Module selection example
Product name
Power supply module (Q Series new)
Power supply module (for extension base unit)
CPU module
Main base unit
Extension base unit (1st stage)
Extension base unit
QA conversion adapter module
Extension cable
Input module
Output module
*1: Select the module depending on the existing program capacity and contents.
*2: Used to mount the Q Series CPU.
*3: Used to mount modules on the existing main base unit.
*4: Select the cable length according to the arrangement of base units.
Tip
• The existing A (Large type) Series extension base unit and mounted modules can be utilized without wiring
modification.
The existing A (Large Type) Series extension base unit can be used without modifying the wiring by replacing
with the extension base QA6 B, and remounting the mounted modules.
• Program modifications can be minimized by using the same I/O address for the existing units and setting the
current I/O addresses with the parameter I/O assignments.
• The following A (Large Type) Series module cannot be used with the Q Series CPU. These must be changed
to a Q Series CPU compatible module.
CC-Link master/local module
MELSECNET/10 network module
Ethernet module
Ethernet module, computer link module
etc.
• The A (Large Type) Series A6 B/A5 B extension base unit with the QA6ADP cannot be used together with
the QA1S6 B extension base unit.
• When an AC input module is mounted on the "A5 B" extension base unit (without power supply) using the
QA6ADP, either the "A6 B with QA6ADP" or "QA6 B" extension base unit (with power supply) is required in
the system.
• Set the stage number for QA6ADP according to the setting of the extension base unit.
• The QA6ADP QA conversion adapter is only compatible with High Performance Model QCPU or Universal
Model QCPU (first five digits of serial No. "13102" or higher).
Basic Model QCPUs, Process CPUs, Redundant CPUs, Safety CPUs, and Remote I/O Stations are not
compatible.
• For the precautions and restrictions when using QA conversion adapter, refer to "QA6ADP QA Conversion
Adapter Module User's Manual".
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
3.1 Replace A/QnA (Large Type) Series with Q Series
Existing module
N/A
A61P (main/extension base unit)
A3ACPU
A35B
N/A
A65B
N/A
N/A
Use existing module in original state
Use existing module in original state
75
Replacement module
-
Q61P
Utilize existing module
3
1
Q03UDCPU*
1
1
Q35B*
2
-
QA65B*
3
Utilize existing module
2
-
QA6ADP
-
QC06B*
4
1
-
1
1
1
-
2
3