4.2 Replace one of A Series stations with Q Series while retaining MELSECNET(ΙΙ)
● Module selection example
Product name
Power supply module
CPU module
Main base unit
Input module
Output module
MELSECNET(Ⅱ) local station data link module
Extension base (for A1S Series module)
Extension Power supply module
(for A1S Series module)
Extension cable
● Link parameter settings (MELSECNET(ΙΙ) composite mode)
Send range (first half)
Station No.
Points
Start
M
256
000
IIL1
256
100
IIL2
256
200
L3
256
300
Tip
1. The data link module was designed for local stations and cannot be set as master station. For this reason,
a local station that is upgraded to Q Series cannot become the master station. Instead, one of the existing
A Series local stations should be set as the master station. The station numbers should be changed
accordingly, but the I/O address and parameters can remain the same.
2. Minimal setup is required, as network parameter settings (excluding link refresh setting) are automatically
detected by the local station data link module. FROM/TO instructions within sequence program (refresh
program) are required to enable send/receive cyclic data.
A sample program to enable send/receive of cyclic data can be created by "A/QnA -> Q conversion
support tool" (which can be downloaded from the MELFANSweb). (Refer to Section 9.2)
3. For MELSECNET(II), the station numbers must be assigned in the connecting order starting from the new
master station.
4. The QA1S51B extension base without power supply module can be used for the local station data link
module mounting base.
Note that the voltage drop must be calculated if the extension cable is long.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
A61P
A3ACPUP21
A38B
AX
AY
Embedded in CPU module
N/A
N/A
N/A
Send range (second half)
End
Points
Start
End
0FF
256
500
5FF
1FF
256
600
6FF
2FF
256
700
7FF
3FF
-
-
-
91
Existing model
1
1
1
1
Station No.
Send range (first half)
Current
New
Points
IIL1 ->
M
256
Replace
IIL1
IIL2 ->
256
L3 ->
L2
256
IIL3
M
->
256
Replacement model
Q61P
Q02HCPU
Q38B
QX
QY
A1SJ71AP23Q
QA1S65B
A1S61PN
QC06B
Send range (second half)
Start
End
Points
Start
100
1FF
256
600
200
2FF
256
700
300
3FF
-
-
000
0FF
256
500
1
1
1
1
1
1
1
End
6FF
7FF
-
5FF