Using The Lcd Screen - Toshiba VLP Technology Q9 Plus Installation & Operation Manual

Asd
Table of Contents

Advertisement

Using the LCD Screen

The LCD screen is the primary user input/output information center. Parameter settings may be viewed or
changed using the LCD display unit of the EOI. To view or change a parameter setting using the LCD
screen, press the Mode key until the Program menu is displayed. Turn the Rotary Encoder until the
desired Primary Menu item (see
the item from the Primary Menu (repeat for submenu items).
See the section titled
settings.
Upon reaching the desired parameter selection, the current setting may be viewed, or selected and changed
by pressing the Rotary Encoder and the setting will take on the reverse video format (dark background/
light text). Turn the Rotary Encoder to change the parameter setting. Press the ESC key while the new
parameter setting is in the reverse video mode to exit the selection without saving the change or press the
Rotary Encoder while the parameter setting is in the reverse video mode to accept the change.
Repeated ESC key entries at any time takes the menu back one level each time the ESC key is pressed
until the Frequency Command screen is reached. Further ESC entries will toggle the system to and from
the Frequency Command screen and the EOI Command menu.
Note:
Changes carried out from the EOI Command screen will be effective for EOI-
controlled ASD operation only. See the section titled
further information on
Primary Menus of the LCD Screen
The three primary screens of the LCD screen are displayed while accessing the associated operating
mode: the Frequency Command, Monitor, and the Program Menu screens.
Figure 22. Frequency Command Screen.
Speed Reference %
Speed Reference Hz
User-Selected
Monitored Parameters
(see
Main Monitor on pg.
54)
Discrete I/O Terminal Status
or Alarm Condition
Figure 23. Monitor Screen (see
Screen Name
Active Frequency
Command
Active DC Bus Voltage
Figure 24. Program Menu Screen (see
Screen Name
Primary Menu Items
30
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
pg.
46) is within the cursor block. Press the Rotary Encoder to select
Default Setting Changes on pg. 35
EOI Command Mode
pg. 43
for more on the Monitor screen items).
pg. 46
for more on the Program Menu Screen).
{
for more information on changing parameter
EOI Command Mode on pg. 42
operations.
Not-Ready-to-Run
Indicator (ST-to-CC required)
Ready-to-Run Indicator
(appears when ST is connected
to CC)
Forward Run Active
Reverse Run Active
Item Number 1 of 43
Monitored Items
(only 5 items listed)
Speed at Trip (if applicable)
Active Output Current
ASD Output Voltage
Item Number 1 of 15
Program Menu Items
(only 5 items listed)
Q9 Plus ASD Installation and Operation Manual
for

Advertisement

Table of Contents
loading