F003
Command Mode
Program Fundamental Standard Mode Selection
The Command Mode Selection establishes the source of the command input
for the ASD. Command inputs include Run, Stop, Forward, etc. The Override
feature may supersede the Command Mode Selection setting (see
Mode and Frequency Mode Control on pg.
Settings:
0 — Terminal Board
1 — Panel Keypad
2 — RS485 2-Wire (EOI Keypad)
3 — RS485 4-Wire (Terminal Board)
4 — Communication Option Board
Frequency Mode 1
Program Fundamental Standard Mode Selection
The Frequency Mode 1 setting establishes the source of the frequency-control
input for the ASD. The Frequency Mode 2 setting or the Override feature may
supersede the Frequency Mode 1 setting.
Note:
Only Bolded items from the Settings list below may be placed in
the Override Mode. See the section titled
Frequency Mode Control on pg. 36
the Override feature.
Settings:
1 — V/I
2 — RR
3 — RX
4 — Panel Keypad
5 — RS485 2-Wire (EOI Keypad)
6 — RS485 4-Wire (Terminal Board)
7 — Communication Option Board
8 — RX2 Option
9 — Option V/I
10 — UP/DOWN Frequency
11 — Optional RP Pulse Input
12 — Optional High-Speed Pulse Input
Q9 Plus ASD Installation and Operation Manual
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
Command
36).
Command Mode and
for additional information on
Direct Access Number — F003
Parameter Type — Selection List
Factory Default — Terminal Board
Changeable During Run — No
Direct Access Number — F004
Parameter Type — Selection List
Factory Default — RR
Changeable During Run — No
F004
83